Maximize your Availability

Highly available, redundant, and scalable double conversion on-line power protection

15 kVA Single Phase Uninterruptible Power Supply UPS

Phase:
Single/Three phase
Input voltage:
220/380V, 230/400V ±20% or customized
Output voltage:
220/380V, 230/400V ±1-5%
Frequency:
50/60Hz
Power factor:
0.8-1
Type of technology:
Servo type with roller carbon brush
Type of regulation:
Independent voltage control
Display:
LED/Touch Screen HMI
Installation:
Indoor/Outdoor

500-1200VA Uninterruptible Power Supply, Off-Line UPS for High Quality, High efficiency and Energy Saving, Power failure

Description:

We are Manufacturer which specialized in Servo Voltage Stabilizer, Uninterruptible Power Supply (UPS), Active Power Filter, etc for nearly 40 years. And be vendor of Mitsubishi Elevator in East Africa, GE, Emerson.

Elementary for data protection

The off-line UPS is in standby status with batteries being charged in normal AC time.When the power supply unexpectedly shuts down, the built-in inverter will in no time convert the battery output into AC to keep stable power supply.

The UPS is generally considered high rate, low noise while running and cost-effective, mostly used in comparably stable environment with a small fluctuation of utility power and lower requirement of power supply quality.

The UPS now is widely used in protection of PC in govemment offices, education institutes and SMEs.

Functions & features:

  • Micro controller(CPU)
  • Waveform:square wave(battery mode)
  • Wide AVR range
  • Overload and short circuit protection
  • Low battery alarm
  • UPS Auto on when AC recovery
  • Off mode charging
  • Humidity:less than 90%

Features

  • It adopts standard frame structure design.
  • The structure is compact. Sine wave output no matter in AC mode or battery mode can provide sine wave power source with low distortion.
  • It provides the best power source guarantee for the load equipments of users.
  • Zero-delay:when the utility power is cout off or recover, there is absolutely no time between the transfer of AC mode and battery mode.
  • It effectively ensures the reliability of load operation.
  • Input null line and fire wire detecting function:it can detect if the null line and fire wire are wrongly connected.
  • It avoids wrong connection of null line and fire wire of UPS AC power input.
  • It has voltage breakthrough protection and strong anti-interference function.
  • Input power factor correction:UPS can correct the input power factor.
  • Under full load, the input power factor can reach over 0.95so that the electric environment of the users will not be polluted