Transforming Electricity into Value

Used as isolation transformers or to adjust the voltage level in the LV distribution grid

80 kVA Single Phase Isolation Transformer

Phase:
Single/Three phase
Input voltage:
220/380V, 230/400V ±20% or customized
Output voltage:
220/380V, 230/400V ±1-5%
Frequency:
50/60Hz
Power factor:
0.8-1
Type of technology:
Servo type with roller carbon brush
Type of regulation:
Independent voltage control
Display:
LED/Touch Screen HMI
Installation:
Indoor/Outdoor

80 kVA Single Phase Isolation Transformer 380V/400V IP20 Indoor Energy Saving Transformer With GPRS

Quick Detail:

Energy Saving Transformer-EST 200KVA help you reduce voltage and save energy.

Dimension(W×D×H)mm: 400×800×800

Description:

Many types of electrical equipment work perfectly well on a voltage lower than the standard mains supply. This is particularly true for equipment designed to operate on 380V or 400V three phase supplies where the supply is 415V. The actual power supply is higher than necessary the equipment will consume more power than needed and in many cases, equipment life is reduced, effectively increasing the cost of ownership.

Energy Saving Transformer (EST) helps organizations make some of the biggest financial savings possible on their energy bills by reducing the mains voltage used to power electrical equipment. It is a tapped auto-transformer which reduces voltage by up to 12% by a fixed amount, making it ideal for sites with a reasonably stable voltage supply. At full load the EST Voltage Optimization delivers efficiency of more than 99% which can realize energy savings of up to 20%.

80 kVA Single Phase Isolation Transformer

Specifications:

Input Voltage Maximum 440V three phase
Output Voltage Maximum nominal reduction of 12%
Output Adjustment 3 fixed taps of 6%, 8% & 10%(other upon request)
Supply Frequency 50/60Hz
Waveform Distortion None
Insulation Class H class
Duty Type Continuous
Cooling Type Natural Air(AN)/Forced Air(AF)
Efficiency >99% at full load
Electrical Safety CE equivalent
Operational Temperature -20 °C to +45 °C
Relative Humidity <90% non-condensing
Enclosure IP20(indoor), outdoor on request
GPRS Remote control and monitoring the VO unit parameters

Competitive Advantage:

  • Energy saving of up to 20%
  • Fast return of investment(ROI) time
  • Prolonged equipment life span
  • High operational efficiency
  • Adjustable configurations based on site requirements
  • Display of input and output voltages and output current
  • Internal protection against overheating
  • Optional GPRS and Wireless Energy Monitors for real-time energy monitoring
  • Single and three phase up to 1000KVA

FAQ

Feedback

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.